Installation Dimensions and Clearances
This reference page provides the physical dimensions, cabinet cut-out requirements, clearance specifications and electrical data needed to install the Oven Studio 800 in a built-in housing unit.
Appliance dimensions
| Measurement | Value |
|---|---|
| Width | 595 mm |
| Height | 595 mm |
| Depth | 567 mm |
| Weight | 38 kg |
Cabinet cut-out dimensions
| Measurement | Value |
|---|---|
| Cut-out width | 560 mm |
| Cut-out height | 590 mm |
| Cut-out depth | 550 mm |
Required clearances
| Position | Minimum clearance |
|---|---|
| Each side | 5 mm |
| Top | 5 mm |
| Rear ventilation gap | 45 mm minimum |
Important: The 45 mm rear ventilation gap is a minimum requirement. Do not push the oven flush against the back wall of the cabinet. Insufficient rear clearance will cause overheating, may trigger the E05 thermal cut-out and will void the warranty.
Electrical requirements
- Supply voltage: 230V~ 50Hz
- Maximum current draw: 13A
- Circuit: Dedicated circuit recommended (not shared with other high-draw appliances)
- Cable length: 1.2 m (factory-fitted, non-detachable)
- Plug type: UK 3-pin 13A fused plug (fitted)
Installation notes
- The unit weighs 38 kg — a two-person lift is required to place it into the housing unit safely
- Ensure the cabinet floor can support the full weight of the loaded oven (appliance plus food, approximately 50 kg total)
- Route the power cable so it does not contact the rear of the oven, where temperatures may exceed 80°C during use
- The oven must be secured to the cabinet using the four fixing screws provided (accessed through the door frame)
Installer tip
Before sliding the oven into the cabinet, connect the plug to the socket and power on to verify the display lights up and responds to controls. This confirms the unit is functional before it is fixed in place and avoids the need to remove it again immediately.