AirCore P2 Easy · 2 min

Filter Indicator Not Resetting After Replacement

Symptoms

Likely Causes

  1. Filter counter was not manually reset after replacement — it does not reset automatically
  2. The new filter is not the correct part (the sensor calibration differs by filter type)
  3. The filter access panel was not fully closed after installation
  4. App and device are out of sync

Step-by-step Fix

  1. Confirm the filter access panel on the rear of the unit is fully closed — press both side tabs firmly until they click. An open or partially closed panel prevents the filter sensor from reading correctly.
  2. Reset the filter counter manually: press and hold the Filter button on the top panel for 5 seconds. The filter indicator will briefly display 100% to confirm the reset. The button is marked with a filter icon.
  3. If resetting via the app: go to Devices > AirCore P2 > Filter > Reset Filter Life. Confirm the action.
  4. Confirm the replacement filter is a genuine Monverta P2 filter (part MV-FLTR-P2 or MV-FLTR-P2-PLUS for the premium version). Third-party filters may not trigger the correct sensor response.
  5. Cycle the power — switch the unit off, unplug, wait 10 seconds, reconnect and power on. The updated filter reading should now display.

Still not working?

If the indicator resets but immediately returns to low or the reading remains frozen, there may be a sensor fault. Contact support at support.monverta.com for diagnostics assistance.